Model |
GTZL-8C25W |
GTZL-8C35W |
GTZL-8C55W |
GTZL-8C75W |
GTZL-8C100W |
GTZL-8C150W |
|
Temperature control range |
-80 ℃ ~ 250 ℃ |
||||||
Temperature control mode |
Feedforward PID,PLC module control |
||||||
Controller |
7 inch color touch screen display and input, temperature curve display, record |
||||||
Compressor |
American Copeland |
||||||
Refrigerant |
R-404A R-23 |
||||||
Separator |
Emerson |
||||||
Evaporator |
Taiwan Gaili plate exchanger |
||||||
Electrical |
Schneider |
||||||
Temperature control object |
Material temperature control and jacket temperature control free choice. |
||||||
Communication |
RS485 MODBUSRTU Protocol |
||||||
Cooling mode |
Air cooling or water cooling (W type) |
||||||
temperature feedback |
Thermal medium temperature feedback PT100 Material temperature feedback PT100 |
||||||
Temperature control accuracy |
± 1 ℃ |
||||||
Heating power |
2.5KW |
3.5KW |
5.5KW |
7.5KW |
10.0KW |
15.0KW |
|
Refrigeration capacity ℃ |
250 |
2.5KW |
3.5KW |
5.5KW |
7.5KW |
10.0KW |
15.0KW |
|
100 |
2.5KW |
3.5KW |
5.5KW |
7.5KW |
10.0KW |
15.0KW |
|
20 |
2.5KW |
3.5KW |
5.5KW |
7.5KW |
10.0KW |
15.0KW |
|
0 |
2.5KW |
3.5KW |
5.5KW |
7.5KW |
10.0KW |
15.0KW |
|
-20 |
2.5KW |
3.5KW |
5.5KW |
7.5KW |
8.5KW |
14.0KW |
|
-40 |
1.8KW |
2.55KW |
3.3KW |
5.8KW |
6.3KW |
11.0KW |
|
-60 |
1.0KW |
1.4KW |
1.6KW |
3.0KW |
3.3KW |
5.8KW |
|
-75 |
0.3KW |
0.42KW |
0.7KW |
1.3KW |
1.4KW |
2.4KW |
Circulating pump flow Volume, pressure |
Max20L/min 2BAR |
Max35L/min 2BAR |
Max50L/min 2BAR |
Max110L/min 2.5BAR |
Max110L/min 2.5BAR |
Max110L/min 2.5BAR |
|
Security Protection |
With self-diagnosis function; freezer overload protection; high-pressure pressure switch, Overload relay, thermal protection device, low liquid level protection, high temperature protection, sensor fault protection and other security functions |
||||||
closed circulation system |
The whole system is a fully closed system, high temperature will not have oil mist, low temperature does not absorb moisture in the air, The system will not increase the pressure due to high temperature during operation, and the low temperature will automatically supplement the heat conduction medium. |
||||||
Interface size |
DN15 PN10 |
DN20 PN10 |
DN20 PN10 |
DN20 PN10 |
DN25 PN10 |
DN25 PN10 |
|
Water-cooled type W Water temperature 20 degrees |
1200L/H 1.5bar~4bar |
1400L/H 1.5bar~4bar |
1900L/H 1.5bar~4bar |
2600L/H 1.5bar~4bar |
3400L/H 1.5bar~4bar |
4500L/H 1.5bar~4bar |
|
Overall dimension |
500*600*1350 |
600*700*1550 |
700*700*1650 |
700*800*1650 |
1000*800*1650 |
1000*950*1650 |
|
Weight |
240KG |
285KG |
345KG |
500KG |
600KG |
750KG |
|
Power |
AC380V50HZ 6.5KW (max) |
AC380V50HZ 10KW (max) |
AC380V50HZ 13KW (max) |
AC380V50HZ 17KW (max) |
AC380V 50HZ 22KW (max) |
AC380V50HZ 33KW (max) |
Quality Assurance
Ensure that the goods sold are brand new products that meet the requirements of the contract and are qualified by the factory inspection, and that the quality, performance, technical indicators and configuration are in accordance with the contract and the manufacturer's technical documents.
Installation and commissioning
After arrival, if on-site installation and debugging are required, our company or our company's agent shall be responsible for the installation and debugging of the instrument.
Acceptance
After installation and commissioning, the customer shall confirm that the goods are brand-new products in accordance with the contract, and that the quality performance, technical indicators and random configuration are in accordance with the contract and the manufacturer's technical documents, and after confirming the acceptance of the full set of technical documents, sign the installation acceptance report to confirm the acceptance.
Training
At the same time of equipment installation and commissioning, our company's after-sales service engineer is responsible for on-site technical training for users until users can operate skillfully. During the use of the instrument, customers can consult the after-sales service personnel of our company for relevant technical problems at any time, and arrange on-site training or remote guidance by our company according to the situation.
After-sales service
From the date of acceptance, a one-year free warranty will be provided, and all maintenance costs and spare parts costs during the warranty period will be free (the cost price of spare parts will be charged for instrument failure caused by human factors); After the warranty period, the equipment will be responsible for maintenance for life and will be charged appropriately according to the actual maintenance cost.
Service Commitment
After receiving the customer's written repair, respond within 24 hours; and according to the customer's location, arrive at the scene within 48 hours to solve.
Key words:
Heating and cooling temperature control system
Heating refrigeration circulator
Low temperature refrigeration circulator
Heating circulator
Positive pressure explosion-proof
Isolation and explosion-proof
Cooling water circulator