Heating and cooling temperature control system LRVS 50 ℃ ~ 300 ℃

Consultation

 

Model

LRVS-

3030

LRVS-

5030

LRVS-

7030

LRVS-

10030

LRVS-

15030

LRVS-

25030

LRVS-

38030

LRVS-

60030

LRVS-

95030

Temperature control range

50 ℃ ~ 300 ℃

Controller

7 inch color touch screen display and input, temperature curve display, record

Temperature control mode

Feedforward PID,PLC module control

Cooling method

Water cooling

Heating mode

Electric heating

Cooler

plate exchanger

Temperature control object

Thermal medium outlet temperature control

temperature feedback

Thermal medium temperature feedback PT100

Medium temperature control accuracy

± 0.5 ℃

± 1 ℃

Material temperature control accuracy

± 0.5 ℃

Heating power

3.5KW

5.5KW

7.5KW

10.0KW

15.0KW

25.0KW

38.0KW

60.0KW

95.0KW

Cold

But

Can

Force

300 ℃

3.5KW

5.5KW

7.5KW

10.0KW

15.0KW

25.0KW

38.0KW

60.0KW

95.0KW

 

200 ℃

3.5KW

5.5KW

7.5KW

10.0KW

15.0KW

25.0KW

38.0KW

60.0KW

95.0KW

 

100 ℃

2.8KW

4.0KW

5.0KW

7.0KW

12.0KW

20.0KW

30.0KW

48.0KW

76.0KW

 

65°C

1.0KW

1.8KW

2.2KW

3.0KW

5.0KW

8.5KW

12.0KW

19.0KW

30.0KW

 

 

Only when cooling is needed, the heat exchanger in the system will automatically open the valve to pass into the cooling water, and close the valve at other times to save water resources.

Circulating pump flow

Volume, pressure

Max30L/min

2.0BAR

Max30L/min

2.0BAR

Max50L/min

2.0BAR

Max50L/min

2.0BAR

Max110L/min

2.0BAR

Max150L/min

2.0BAR

Max200L/min

2.0BAR

Max250L/min

2.0BAR

Max400L/min

2.0BAR

Safety protection

With self-diagnosis function; anti-dry protection, overload relay, phase sequence protection and other security functions.

closed cycle

System

The whole system is a fully closed system, there will be no oil mist at high temperature, and the water in the air will not be absorbed at low temperature. The system will not increase the pressure due to high temperature during operation, and the heat conduction medium will be automatically supplemented at low temperature.

Interface size

G3/4

G3/4

G1

G1

G1

DN32

DN40

DN40

DN50

Exterior dimension

mm

450*650*800

450*650*800

550*680*1150

550*680*1150

700*800*1650

700*800*1650

700*800*1650

1500*1000*1750

1500*1000*1750

Weight

70KG

75KG

85KG

100KG

160KG

200KG

280KG

550KG

800KG

Power AC380V50HZ

5.5KW 

7.0KW

9.0KW

12.0KW

17.0KW

28.0KW

41.0KW

65.0KW

101.0KW

Shell material

Spray plastic for cold-rolled sheet

Power supply option

AC three-phase 220V 60HZ ,AC three-phase 440V ~ 480V 60HZ

Explosion-proof optional

ExdIIBT4 or ExdIICT4

4
3
2
1
E4
E3
E2
E1
图片名称
图片名称
Picture Name

Quality Assurance

Ensure that the goods sold are brand new products that meet the requirements of the contract and are qualified by the factory inspection, and that the quality, performance, technical indicators and configuration are in accordance with the contract and the manufacturer's technical documents.

Picture Name

Installation and commissioning

After arrival, if on-site installation and debugging are required, our company or our company's agent shall be responsible for the installation and debugging of the instrument.

Picture Name

Acceptance

After installation and commissioning, the customer shall confirm that the goods are brand-new products in accordance with the contract, and that the quality performance, technical indicators and random configuration are in accordance with the contract and the manufacturer's technical documents, and after confirming the acceptance of the full set of technical documents, sign the installation acceptance report to confirm the acceptance.

Picture Name

Training

At the same time of equipment installation and commissioning, our company's after-sales service engineer is responsible for on-site technical training for users until users can operate skillfully. During the use of the instrument, customers can consult the after-sales service personnel of our company for relevant technical problems at any time, and arrange on-site training or remote guidance by our company according to the situation.

Picture Name

After-sales service

From the date of acceptance, a one-year free warranty will be provided, and all maintenance costs and spare parts costs during the warranty period will be free (the cost price of spare parts will be charged for instrument failure caused by human factors); After the warranty period, the equipment will be responsible for maintenance for life and will be charged appropriately according to the actual maintenance cost.

Picture Name

Service Commitment

After receiving the customer's written repair, respond within 24 hours; and according to the customer's location, arrive at the scene within 48 hours to solve.

Key words:

Heating and cooling temperature control system

Heating refrigeration circulator

Low temperature refrigeration circulator

Heating circulator

Positive pressure explosion-proof

Isolation and explosion-proof

Cooling water circulator

Other products




Other Products

Refrigeration Circulator -120 ℃

Refrigeration Circulator -120 ℃

Refrigeration Circulator -120 ℃

Refrigeration Circulator -120 ℃

Introduction




Online consultation

%{tishi_zhanwei}%